FREE MVHR SYSTEM ESTIMATE - SEND DRAWINGS TO SALES@THEAIRSHOP.CO.UK


		



		
		
		
			
		
Rear Entry
Integral Damper

ResiAIR Air Distribution Manifold Rear Entry 160mm 6 x 90mm Ports

£217.80 (inc VAT)

£8.99

RA-RE-160-690

The ResiAIR™ Air Distribution Manifold - Rear entry 160mm 6 x 90mm ports manifold is designed to efficiently distribute air between the MVHR unit and multiple semi-rigid radial ducts. Designed for rear entry to 160mm duct connection, internal acoustic lining and 6 x 90mm ports, it provides a flexible and space-efficient solution for MVHR and ventilation systems. 

  • Rear entry - Ideal for installlation in ceiling, loft, wall or inbetween joists.
  • 160mm safe seal connection - provides an airtight connection at source
  • 6 x 90mm ports - allows connection of multiple radial ducts to varying rooms
  • Quiet airflow with internal acoustic lining - helps reduce noise transmission through the ductwork
  • Unique integral dampers at each port - allows airflow to be balanced and adjusted during commissioning with ease
  • Box contains - 1 x RA-RE-160-690 & 1 x blanking end cap

Compatible with ResiAIR™ semi rigid ducting from The Air Shop

Product Info and Downloads

Performance

Optimal Airflow Distribution – Helps distribute airflow efficiently and evenly across connected radial duct runs.

Flexible Installation – Available in rear, top and side entry configurations to suit different ventilation system layouts and installation requirements.

Acoustic Performance – Internal acoustic lining helps reduce noise transmission through the manifold and connected ductwork.

Commissioning Control – Integral commissioning dampers allow individual airflow paths to be adjusted and balanced during system commissioning.

Durable Construction – Manufactured from high-quality materials designed for reliable, continuous use within ventilation systems.

Installation

Suitable for use with ResiAIR™ 90mm semi-rigid radial ducting and compatible ventilation components.

Connect the Main Duct – Connect the manifold to the main ventilation duct using the appropriate duct connection size.

Connect Ducting – Connect the 90mm radial duct runs to the manifold ports using the appropriate sealing rings and click rings to create secure, airtight connections.

Seal Unused Ports – Use suitable blanking caps or end caps on any unused manifold ports to prevent unwanted air leakage and contamination.

Commission the System – Adjust the integral commissioning dampers as required to balance airflow across the connected duct runs.

Check Connections – Ensure all connections are fully secured and sealed before operating and commissioning the ventilation system.

General Info

What is an MVHR System and what is it doing for my home?

Improvements in modern building techniques means that our homes are becoming more airtight than ever, which is great for insulation however it can leave stale air, foul smells, condensation and damp. An MVHR (Mechanical Ventilation and Heat Recovery) system is a complex ventilation system that extracts polluted air from your home and replaces it with a filtered and clean air supply whilst recovering the heat for your home.

The unit itself is either located in a utility cupboard or loft. Newer homes fitted with these systems have a much better indoor air quality if the system is commissioned and serviced regularly.

So, what are the benefits?

An MVHR system supplies fresh air into your home through a low-energy heat exchange meaning that your home is getting a consistent fresh air supply. This balanced ventilation works effectively in both the winter and the summer. The heat recovery aspect of an MVHR system recovers heat that would otherwise be lost through other ventilation systems at up to a 95% rate of efficiency. This means that the demand on your properties heating systems are reduced greatly saving you money on utilities and reducing your carbon footprint. The fact that the system is working year round means that a well-balanced system will reduce the likelihood of mould or condensation in your property which thrives in moist and humid room corners. This can massively help in alleviating airborne allergies and asthma symptoms as the air is much purer. By filtering the air, MVHR systems tackle odours and Volatile Organic Compounds (VOCs) that can be found in household products and are detrimental to your health. These harmful compounds are filtered out protecting you and improving the overall internal environment in which you live.

Delivery & Returns

  • The Air Shop uses FedEx for shipping and a tracking number is provided (if alternative courier is used, this will be advised through tracking confirmation information)
  • Our standard is 48-hour shipping – orders arrive 2 days after purchase (If ordered before 12pm orders arrive next day)
  • Your delivery date will be advised within 24 hours of completion of order based on stock availability
  • Delivery is available Monday – Friday (if alternative is required, please call to discuss)
  • The Air Shop cannot be held responsible for delivery delays by the courier
  • Orders over 30kg are excluded from free shipping and a charge will apply which will be shown on checkout


Multiple Unit Orders & Larger Pallet
If you are wanting to purchase multiple units for a larger project or require a pallet delivery we will provide a separate and personalised quote for this. Please contact our office 033 0223 6776 or email sales@theairshop.com


Collection
Orders are available for collection, please contact us on 033 0223 6776 or email sales@theairshop.com to confirm your item Is in stock and agree a date/time.

Opening Hours
Monday – Friday / 8:00am – 5:30pm
13 Market Road, Richmond, London, TW9 4LZ

Back orders If your item is out of stock, we will back order if for you or give you the option to cancel .

Specifications

Duct connection: 160mm ø
Number of ports: 6
Port size: 90mm
Dimension (mm): 400 x 130 x 260
SKU:  RA-RE-160-690
Warranty: 2 Years